Popular topics: Downloads Can I connect my computer wirelessly to the projector? HDL300 system installation guide Download Room Manager Room Manager features overview ► WM408i installation guide and drawings ► HDL300 system integration guide More download options Microphone clearance requirements and recommendations Does the HDL300 system work with audio conferencing (UC&C) software? Installation guides and drawings Using the auxiliary ports on the HDL300 system Span Workspace technical requirements HDL300 and Dual HDL300 system connection diagrams Getting started with your HDL300 system Installing a Dual HDL300 system Is the HDL300 system compatible with the Cisco® SX80? Setting up Jira® for Span Workspace ► Copying and pasting onto the canvas WM210i and WM307i technical requirements

Is the HDL300 system compatible with the Biamp™ Tesira FORTÉ® DAN VT?

Yes, the biamp audio digital signal processor (DSP) is compatible with the HDL300 system. To connect the two systems, two cables will be needed.

To get started, first check that the HDL300 is up-to-date and set up correctly:

On your PC

  1. Connect a USB-A to USB-B cable from your laptop to the Connect Module
  2. Download and run Nureva Room Manager
  3. In Nureva Room Manager, under 
    1. Product updates => Check for firmware updates
    2. Audio conferencing system
      1. Controls
        1. Microphones => set the mic level to 80%
        2. Speakers => set the volume level to 100%
        3. Auxiliary ports
          1. Aux out => Microphone out (Mic level)
          2. Sleep mode => Disable
  4. Disconnect the connect module from your laptop and remove the USB cable.


Custom cables

Cable 1:  Prepare a 3.5 mm jack cable with the three pins positive (+), negative () and ground (G), wired to an appropriate Euroblock 3-terminal block as described in the TesiraFORTÉ user manual.

Cable 2: Prepare a second 3.5 mm jack cable with the three pins positive (+), negative () and ground (G), wired to an appropriate Euroblock 3-terminal block as described in the TesiraFORTÉ user manual.


On the connect module

  1. Plug Cable 1 into the Aux Out port
  2. Plug Cable 2 into the Aux In port
  3. Connect the PoE cable (provided) to the RJ45-1 port on the connect module to the rear RJ45 port on the HDL300 system
  4. Plug in the  power supply


On the Biamp Tesira FORTÉ DAN VT

  1. Plug Cable 1 Euroblock connector into Input - Channel 1 (orange) on the rear I/O panel
  2. Plug Cable 2 Euroblock connector into Outputs - Channel 1 (black)
  3. Connect the Tesira FORTÉ to the network using the LAN port
  4. Connect the power source


In the Biamp SAGEVUE software

  1. Disable the AEC for all Input channels. Echo cancellation is performed within the HDL300 system and does not require additional signal processing
  2. Adjust the Biamp input/output channels to match the HDL300 system's design requirements per the table below.

These configurations prevent clipping during normal call operations with the HDL300 system. 

  1. Click OK to save the profile settings


Connection Diagram

NOTE: The Nureva Aux In / Out connections are single-ended, unbalanced signals with default maximum output signals as given in the table below. Any equipment requiring voltages below these levels may result in clipping, distortion and, in extreme cases, damage to connected systems. Equipment requiring voltages above these levels will not be adequately driven by the HDL300 system’s output signal and may result in quiet / no audio on the channel. Before connecting to the Nureva Connect Module, make sure the third-party device voltage levels are adequate or adjusted properly by additional interfacing hardware.


Last updated: January 14, 2020

Was this article helpful?

Can’t find what you’re looking for?

Contact Support